SPECIFICATION
|
|
|
|
INFRARED MEASURING RANGE |
-40 °C - 600 °C
|
|
|
|
|
|
|
|
|
ACCURACY:
|
|
|
|
± 1 °C |
-10 °C - 60 °C
|
|
|
|
|
|
± 1.5 °C |
< 10 °C and > 60 °C
|
|
|
|
|
|
± 1.5 % |
whichever value is greater
|
|
|
|
|
|
AMBIENT TEMPERATURE |
-10 °C to 60 °C
|
|
|
|
|
|
ACCURACY |
± 2 °C
|
|
|
|
|
|
HYGROMETER |
20 % - 90 % relative air humidity
|
|
|
|
|
|
ACCURACY |
± 3%
|
|
|
|
|
|
DEW POINT INDICATOR |
-20 °C - 60 °C
|
|
|
|
|
|
OPTICS 8:1 |
8 m distance : 1 m measured spot
|
|
|
|
|
|
EMISSION COEFFICIENT |
0.10 - 0.99; adjustable
|
|
|
|
|
|
LASER WAVELENGTH |
650 nm
|
|
|
|
|
|
LASER |
class 2M, < 5 mW
|
|
|
|
|
|
WEIGHT |
0,185 kg
|
|
|
|
USERS/USES
Infrared thermometer for locating thermal bridges and condensation moisture.
FEATURES
Functions: surface temperature ambient temperature relative air humidity dew point temperature – Temperature measurement in difficult to reach places or in endangered measuring zones – The integrated hygrometer determines relative air humidity and calculates the dew point temperature. – Localisation of thermal bridges and places endangered by the formation of condensation water. – The multi-function display: provides sufficient space for all measured values – Condensation water indicator as bar graph display – Min/Max/Avg display: The smallest, largest or average measured value can be displayed, as needed. – Adjustable emission coefficient (0.10 ... 0.99) – Measurement display in °C or °F, selectable. – Data-Hold: The most recent measured values are saved temporarily. – LCD Backlight: Illuminated LCD – Rubber-cased housing for impact protection
Supplied with: CondenseSpot + Battery + Softbag
POWER SUPPLY Type 9 V E block battery DIMENSIONS (B x H x D) 108 x 161 x 38 mm
ACCESSORIES
|